- Home
- Search Results
- Page 1 of 1
Search for: All records
-
Total Resources2
- Resource Type
-
0000000002000000
- More
- Availability
-
20
- Author / Contributor
- Filter by Author / Creator
-
-
Aramaki, T. (2)
-
Brink, P_L (2)
-
Fink, C_W (2)
-
Ganjam, S. (2)
-
Mahapatra, R. (2)
-
Mirabolfathi, N. (2)
-
Page, W_A (2)
-
Partridge, R. (2)
-
Platt, M. (2)
-
Pyle, M. (2)
-
Sadoulet, B. (2)
-
Serfass, B. (2)
-
Watkins, S_L (2)
-
Zuber, S. (2)
-
CPD_Collaboration (1)
-
Camilleri, J. (1)
-
Defay, X. (1)
-
Hines, B_A (1)
-
Huber, M_E (1)
-
Kolomensky, Yu_G (1)
-
- Filter by Editor
-
-
& Spizer, S. M. (0)
-
& . Spizer, S. (0)
-
& Ahn, J. (0)
-
& Bateiha, S. (0)
-
& Bosch, N. (0)
-
& Brennan K. (0)
-
& Brennan, K. (0)
-
& Chen, B. (0)
-
& Chen, Bodong (0)
-
& Drown, S. (0)
-
& Ferretti, F. (0)
-
& Higgins, A. (0)
-
& J. Peters (0)
-
& Kali, Y. (0)
-
& Ruiz-Arias, P.M. (0)
-
& S. Spitzer (0)
-
& Sahin. I. (0)
-
& Spitzer, S. (0)
-
& Spitzer, S.M. (0)
-
(submitted - in Review for IEEE ICASSP-2024) (0)
-
-
Have feedback or suggestions for a way to improve these results?
!
Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
We present the design and characterization of a large-area Cryogenic PhotoDetector designed for active particle identification in rare event searches, such as neutrinoless double beta decay and dark matter experiments. The detector consists of a 45.6 cm2 surface area by a 1-mm-thick 10.6 g Si wafer. It is instrumented with a distributed network of Quasiparticle-trap-assisted Electrothermal feedback Transition-edge sensors with superconducting critical temperature Tc=41.5 mK to measure athermal phonons released from interactions with photons. The detector is characterized and calibrated with a collimated 55Fe x-ray source incident on the center of the detector. The noise equivalent power is measured to be 1×10−17 W/Hz in a bandwidth of 2.7 kHz. The baseline energy resolution is measured to be σE=3.86±0.04 (stat.)−0.00+0.19 (syst.) eV. The detector also has an expected timing resolution of σt=2.3 μs for 5 σE events.more » « less
-
Fink, C_W; Watkins, S_L; Aramaki, T.; Brink, P_L; Ganjam, S.; Hines, B_A; Huber, M_E; Kurinsky, N_A; Mahapatra, R.; Mirabolfathi, N.; et al (, AIP Advances)In this letter, we present the performance of a 100 μm × 400 μm × 40 nm W Transition-Edge Sensor with a critical temperature of 40 mK. This device has a noise equivalent power of 1.5×10-18 W/Hz, in a bandwidth of 2.6 kHz, indicating a resolution for Dirac delta energy depositions of 40 ± 5 meV (rms). The performance demonstrated by this device is a critical step toward developing a O(100) meV threshold athermal phonon detector for low-mass dark matter searches.more » « less
An official website of the United States government
